CALIBRATION (April
2005):
CALIBRATION OF VERY OLD FIRST UNBALANCED VERSION LANGEVIN ELOP LIMITER
PURPOSE: To calibrate the
ancient first version ELOPs that we haven't built since 1994.
METHOD: To relate the old
board layout to the current Owner's Manual.
UNITS AFFECTED: Serial numbers for units that will benefit from this update are
LOPTO001
(7/1993) through LOPTO021 (2/1994).
FOLLOW CALIBRATION PROCEDURE ON PAGE
11 OF THE CURRENT
OWNER'S MANUAL:
Which can be found online here:
http://www.manleylabs.com/PDF/PRO_Manuals/Langevin/Langevin%20ELOP%20Manual.pdf
REFER TO THE TRIMPOT LOCATIONS AS BELOW

Trimmer "1" adjusts the Power Rail Voltage
Trimmer "2&3" is the Preamp GAIN adjust
Trimmer "6&7" is the Meter Zero Cal
Trimmer "8&9" is the Gain Reduction meter Cal
The other trimpot adjusters referred to in the manual do not exist in this version of Langevin ELOP.
For further info, please contact our service
department.
If you would like to send your unit in and have Paul perform this
calibration for you, please contact him by filling in the SERVICE
FORM or at the address below: